Models
|
Drives in frames
|
Maximum cartridges
|
Maximum native capacity
|
L25, D25, S25, and S24
|
3592 tape drives
|
17,550
|
263 petabytes (PB)
|
L55, D55, S55, and S54
|
LTO tape drives
|
23,170
|
139 PB
|
Note: The maximum native capacity figures are based on library configurations with one base frame with all LTO-7 or TS1155 tape drives, and 17 storage-only HD frames.
|
Frame model
|
Type
|
Media type
|
Capacity
|
Other
|
|
Frame position 1
|
Frame position 2+
|
||||
L25
|
Base frame
|
3592
|
Up to 12 tape drives and 550 storage slots
|
Up to 16 tape drives and 660 storage slots
|
•Equipped with two I/O stations and two 16-slot magazines
•Optionally equipped with top rack (Model TR1)
|
L55
|
Base frame
|
LTO
|
Up to 12 tape drives and 730 storage slots
|
Up to 16 tape drives and 882 storage slots
|
•Equipped with two I/O stations and two 18-slot magazines
•Optionally equipped with top rack (Model TR1)
|
D25
|
Expansion frame
|
3592
|
Up to 12 tape drives and 590 storage slots
|
Up to 16 tape drives and 740 storage slots
|
•Optionally quipped with two I/O stations and two 16-slot magazines
•Optionally equipped with top rack (Model TR1)
|
D55
|
Expansion frame
|
LTO
|
Up to 12 tape drives and 774 storage slots
|
Up to 16 tape drives and 970 storage slots
|
•Optionally equipped with two I/O stations and two 18-slot magazines
•Optionally equipped with top rack (Model TR1)
|
S25
|
Storage-only expansion frame
|
3592
|
798 storage slots
|
1,000 storage slots
|
•Optionally equipped with top rack (Model TR1)
|
S55
|
Storage-only expansion frame
|
LTO
|
1,054 storage slots
|
1,320 storage slots
|
•Optionally equipped with top rack (Model TR1)
|
S24
|
Storage-only expansion frame
|
3592
|
Not supported
|
1,000 storage slots
|
•Optionally equipped with top rack (Model TR1)
|
S54
|
Storage-only expansion frame
|
LTO
|
Not supported
|
1,320 storage slots
|
•Optionally equipped with top rack (Model TR1)
|
Licensed features
|
Frame position
|
Quantity of drives
|
Quantity of I/O slots
|
Quantity of storage slots
|
Entry
|
1
|
1 - 12
|
36
|
100
|
Intermediate
|
1
|
1 - 12
|
36
|
200
|
Base
|
1
|
0 - 12
|
36
|
400
|
Base
|
2+
|
0 - 16
|
36
|
400
|
HD CoD
|
1
|
0 - 12
|
36
|
730
|
HD CoD
|
2+
|
0 - 16
|
36
|
882
|
Important: If a bulk load is performed, the top rows on tier 1 must remain empty to allow for the initial inventory.
|
Note: The left and right side doors also contain the door lock and open sensor.
|
Note: The combined number of D55 or D25 drive frames that can be installed in a TS4500 library is limited to seven.
|
Licensed features
|
Frame position
|
Quantity of drives
|
Quantity of I/O slots
|
Quantity of storage slots
|
Base
|
1
|
0 - 12
|
0 - 36
|
500
|
Base
|
2+
|
0 - 16
|
0 - 36
|
500
|
HD CoD
|
1
|
0 - 12
|
36
|
730
|
HD CoD
|
1
|
0 - 16
|
0
|
774
|
HD CoD
|
2+
|
0 - 16
|
36
|
882
|
HD CoD
|
2+
|
0 - 16
|
0
|
970
|
Licensed features
|
Frame position
|
Quantity of drives
|
Quantity of I/O slots
|
Quantity of storage slots
|
Entry
|
1
|
1 - 12
|
32
|
100
|
Intermediate
|
1
|
1 - 12
|
32
|
200
|
Base
|
1
|
0 - 12
|
32
|
400
|
Base
|
2+
|
0 - 16
|
32
|
400
|
HD CoD
|
1
|
0 - 12
|
32
|
550
|
HD CoD
|
2+
|
0 - 16
|
32
|
660
|
Important: If a bulk load is performed, the top two rows on tier 1 must remain empty to allow for the initial inventory.
|
Important: The combined number of allowed D55 or D25 frames in a TS4500 library is limited to seven.
|
Licensed features
|
Frame position
|
Quantity of drives
|
Quantity of I/O slots
|
Quantity of storage slots
|
Base
|
1
|
0 - 12
|
0 or 32
|
500
|
Base
|
2+
|
0 - 16
|
0 or 32
|
500
|
HD CoD
|
1
|
0 - 12
|
32
|
550
|
HD CoD
|
1
|
0 - 12
|
0
|
590
|
HD CoD
|
2+
|
0 - 16
|
32
|
660
|
HD CoD
|
2+
|
0 - 16
|
0
|
740
|
Attention: The HD slots use a constant force spring to maintain forward pressure on the tape cartridges. Use caution when you insert or remove cartridges from the HD slots.
|
Model
|
Licensed features
|
Frame position
|
Quantity of storage slots
|
S25
|
S25 Base
|
Any
|
0,600
|
S55
|
S55 Base
|
Any
|
0,660
|
S25
|
S25 HD CoD
|
1
|
0,798
|
S55
|
S55 HD CoD
|
1
|
1,054
|
S25
|
S25 HD CoD
|
2+
|
1,000
|
S55
|
S55 HD CoD
|
2+
|
1,320
|
S24
|
S24 HD CoD
|
2+
|
1,000
|
S54
|
S54 HD CoD
|
2+
|
1,320
|
Note: I/O stations are not accessible in the left integrated service bay, so an L25 or L55 frame cannot be used as a left integrated service bay. The frame that ships with the HA option can be installed on the left side if required because no dedicated service bays are on that side. The new accessor must be installed in the frame on the right side.
|
Note: “Use for maximum capacity” is the default setting if the setting is not changed.
|
Note: The integrated FC switches do not require additional power feeds to the TS4500. The integrated FC switches use bifurcated power cords that are provided with the mounting kit hardware for the switches. These power cords connect internally to the existing TS4500 Power Distribution Units.
|
Note: The external TSSC can also be a TSSC/IMC inside another TS4500. This configuration requires that you install FC 2704 on the Lx5 frame. FC 2704 provides a 26-port switch to allow connection to up to 24 additional devices to share the TSSC/IMC.
|
Important: The top rack is treated as an independent rack space, and it is not tied to the service or support of the tape library.
|
Number
|
Component
|
1
|
Library frames
|
2
|
Rail system
|
3
|
Cartridge accessor
|
4
|
Accessor controller
|
5
|
Cartridge storage slots
|
6
|
IBM LTO or 3592 tape drives
|
7
|
Front door
|
8
|
Door safety switch
|
9
|
I/O stations
|
10
|
Integrated management console
|
Number
|
Component
|
11
|
Power cable hole
|
12
|
Fibre Channel cable hole
|
13
|
Frame control assembly
|
14
|
Patch panel
|
15
|
Rear of IBM LTO or 3592 tape drives
|
Number
|
Component
|
16
|
Display panel
|
17
|
I/O stations
|
Important: When you add the new HA feature to an existing TS4500, in addition to ordering the correct length flex track cable, you are required to order FC 2071 or FC 2072 for each existing frame.
|
Note: No drives are installed in the storage-only frames (models S25, S24, S55, and S54).
|
Type of drive
|
Speed of connection
|
Native data rate
|
Native capacity
|
Other information
|
IBM LTO Ultrium 7
|
8 Gbps Fibre
|
300 MBps
|
6 TB
(5.46 TiB)
|
Known as the LTO-7 tape drive, Model 3588 F7C, TS1070
|
IBM LTO Ultrium 6
|
8 Gbps Fibre
|
160 MBps
|
2500 GB
(2.27 TiB)
|
Known as the LTO-6 tape drive, Model 3588 F6C, TS1060
|
IBM LTO Ultrium 5
|
8 Gbps Fibre
|
140 MBps
|
1500 GB
(1.36 TiB)
|
Known as the LTO-5 tape drive, Model 3588 F5C, TS1050
|
IBM TS1155
|
8 Gbps Fibre
for model 55F
10 Gbps Optical Ethernet for model 55E
|
360 MBps
|
900 GB (.82 TB)
with JK cartridge
3 TB (2.73 TiB)
with JL cartridge
7 TB (6.37 TiB)
with JC/JY cartridge
15 TB (13.64 TiB)
with JD/JZ cartridge
|
Known as the 3592 55E or 3592 55F tape drive
|
IBM TS1150
|
8 Gbps Fibre
|
360 MBps
|
900 GB (.82 TB)
with JK cartridge
2 TB (1.82 TiB)
with JL cartridge
7 TB (6.37 TiB)
with JC/JY cartridge
10 TB (9.1 TiB)
with JD/JZ cartridge
|
Known as the 3592 EH8 tape drive
|
IBM TS1140
|
8 Gbps Fibre
|
250 MBps
|
500 GB (.48 TB)
with JK cartridge
1.6 TB (1.46 TiB)
with JB/JX cartridge
4 TB (3.6 TiB)
with JC/JY cartridge
|
Known as the 3592 EH7 tape drive
|
Note: The side doors of the base frames (Lx5) also have a key lock, which is the same key lock that is used for the front door.
|
Important: Use only the eject button (which is numbered 1 in Figure 1-35 on page 41) or the management GUI to open and close the I/O station doors. Do not attempt to open or close the doors manually.
|
Number
|
Function
|
1
|
Eject button.
|
2
|
Open/close state.
Off: Normal state.
Blinking: Transitional state. Whenever the button is pushed, it blinks and goes off when the doors open, and it blinks and comes back on as a solid light if it is locked by a “code”.
On solid: Locked.
|
3
|
Unload is required, or cartridges are present.
Off: No cartridges are present.
Blinking: The I/O station is full so an intervention is required.
On: Several cartridges are present.
|
4
|
No magazine is present.
On solid: No magazine is present.
|
5
|
I/O capacity indicator.
|
6
|
I/O lock status indicator.
|
Note: Do not use tools to tighten the screws on the LFI card connectors, or this can result in cables not being correctly plugged.
|
Number
|
Component
|
1
|
Warning indicator (yellow)
|
2
|
Library beacon (blue)
|
3
|
Power indicator (green)
|
4
|
Upper I/O fullness indicator (green)
|
5
|
Power switch
|
6
|
Power switch cover
|
7
|
Upper I/O lock indicator (green)
|
8
|
Lower I/O fullness indicator (green)
|
9
|
Lower I/O lock indicator (green)
|
10
|
Pause button
|
11
|
Library pause indicator (yellow)
|
12
|
Access recovery button
|
Note: Always pause the library before you power it off. If you power off the library before you pause the library, the library might take longer to come online after the next power-on.
|
Important: For advice about selecting a fire-suppression system that provides the correct level of coverage and protection, consult your insurance underwriter, and local fire marshal (or local building inspector). IBM designs and manufactures equipment to internal and external standards that require certain environments for reliable operation. Because IBM does not test any equipment for compatibility with fire-suppression systems, IBM does not make compatibility claims of any kind nor does IBM provide suggestions about fire-suppression systems.
|
Feature code
|
Model
|
CSU
|
Description
|
1404
|
L25, L55
|
No
|
TS1140 and TS1150 tape drive support.
This FC triggers the shipment of a JK diagnostic cartridge.
When Model L25 is ordered, FC 1404 is required.
When FC 9080 (Mixed Media) is ordered for the Model L55, FC 1404 is required.
|
1405
|
L25, L55
|
Both
|
LTO-6 and LTO-5 tape drive support.
This FC triggers the shipment of an L5 diagnostic cartridge.
When Model L55 is ordered, a minimum of one of FC 1405 or 1407 is required but both can be selected.
When FC 9080 (Mixed Media) is ordered for the Model L25, a minimum of one of FC 1405 or 1407 is required but both can be selected.
|
1406
|
L25, L55
|
No
|
TS1150 and TS1155 tape drive support.
This triggers the shipment of a JL CE cartridge. When model L25 is ordered or when FC 9080 (Mixed Media) is ordered for model L55 a minimum of one of FC 1404 or 1406 is required but any may be selected.
|
1407
|
L25, L55
|
No
|
LTO-7 and LTO-6 tape drive support.
This FC triggers the shipment of an L6 CE cartridge.
When Model L55 is ordered, a minimum of one of FC 1405 or 1407 is required but both can be selected.
When FC 9080 (Mixed Media) is ordered for Model L25, a minimum of one of FC 1405 or 1407 is required but both can be selected.
|
1442
|
D25, D55, L25, L55
|
No
|
Dual accessors.
This FC triggers the shipment of four CE/diagnostic cartridges (two cartridges of the latest generation for both LTO and 3592).
Service Bay Stop-A related parts and Service Bay Stop-B related parts.
TS4500 Accessor B, including scanner, enhanced grippers, and enhanced node cards.
A maximum of one HA kit (1442) per library can be ordered.
|
1450
|
D25, D55
|
No
|
TS4500 frame control assembly (FCA).
|
1460
|
L25, L55
|
No
|
Redundant Accessor Power/Network, which provides power and internal network redundancy for the L25/L55 frame. This is a prerequisite to FC 9002.
|
1521
|
D25, D55, L25, L55
|
No
|
First TS4500 quad drive mounting kit.
Prerequisite: FC 1450 (for Dx5 frame models only).
|
1522
|
D25, D55, L25, L55
|
No
|
Second TS4500 quad drive mounting kit.
Prerequisite: FC 1521. This feature is not supported if the frame is used as an integrated service bay (ISB).
|
1523
|
D25, D55, L25, L55
|
No
|
Third TS4500 quad drive mounting kit.
Prerequisite: FC 1522. This feature is not supported if the frame is used as an integrated service bay (ISB).
|
1524
|
D25, D55, L25, L55
|
No
|
Fourth TS4500 quad drive mounting kit.
Prerequisite: FC 1523. This feature is not supported if the frame is used as an integrated service bay (ISB).
|
1530
|
D25, D55, L25, L55, S25, S55
|
No
|
Web camera mounting hardware. Provides mounting hardware only.
|
1604
|
L25, L55
|
Yes
|
Transparent LTO encryption provides license keys to enable transparent LTO encryption.
|
1628
|
L55
|
Yes
|
Additional LTO Cartridge Magazines. Provides magazine and cover for transport or storage of up to 18 cartridges.
|
1629
|
L25
|
Yes
|
Additional 3592 Cartridge Magazine. Provides magazine and cover for transport or storage of up to 16 cartridges.
|
1643
|
L25, L55
|
Yes
|
Intermediate capacity on demand (CoD) provides a license key to increase storage from entry capacity to intermediate capacity.
|
1644
|
L25, L55
|
Yes
|
Base capacity on demand provides a license key to increase storage from intermediate capacity to base capacity. This feature code is a prerequisite for FC 9002 or Model Lx5 HD CoD FC 164x.
Prerequisite: FC 1643.
|
1645
|
S25
|
Yes
|
High-density capacity on demand.
|
1646
|
S55
|
Yes
|
High-density capacity on demand.
|
1647
|
L25
|
Yes
|
High-density capacity on demand.
Prerequisite: FC 1644.
|
1648
|
L55
|
Yes
|
High-density capacity on demand.
Prerequisite: FC 1644.
|
1649
|
D25
|
Yes
|
High-density capacity on demand.
|
1650
|
D55
|
Yes
|
High-density capacity on demand.
|
1652
|
D25, D55
|
No
|
Two additional I/O stations. This feature code adds either 36 (LTO) or 32 (3592) I/O slots.
|
1682
|
L25, L55
|
Yes
|
Path failover.
|
1742
|
S24, S54
|
No
|
TS4500 Control upgrade. This FC includes 1x top panel and 2x Ethernet cables, card cages, ASCs, BPCs, and LFIs.
|
1750
|
TR1
|
No
|
Left-side and right-side end covers. This feature is required only for the first top rack that is ordered (if multiple top racks are installed on adjacent frames).
|
1751
|
TR1
|
No
|
Power distribution unit FC 1751 provides one PDU to be mounted in the top rack. The first PDU in a top rack does not consume any of the 10U of rack space. The second PDU in a top rack consumes 1U of rack space.
A maximum of two FC 1750s can be ordered.
Prerequisite: For each FC 1751 ordered, one power cord (FC 9954 through FC 9959 or FC 9966) must also be ordered.
|
1802
|
L25, L55
|
No
|
Non-HA 1 - 2 frame X-track cable.
|
1806
|
L25, L55
|
No
|
Non-HA 3 - 6 frame X-track cable
|
1814
|
L25, L55
|
No
|
Non-HA 7 - 14 frame X-track cable.
Not supported by FC 2071 or FC 9071.
|
1818
|
L25, L55
|
No
|
Non-HA 9 - 18 frame X-track cable.
Not supported by FC 2071 or FC 9071.
|
1909
|
L25, L55, D25, D55
|
No
|
Single power source bifurcated cable. This feature allows attachment of a powered frame to a single outlet while it also maintains drive redundant power.
|
1951
|
D25, D55, L25, L55, S25, S55
|
No
|
Power distribution units. This feature provides two PDUs, mounting hardware, including rack brackets, and internal power cables.
FC 1951 supports any combination of up to three pairs of power cords for
FC 4875 on the same frame and FC 9989 on adjacent frames. Corequisite: One power cord feature (FC 9954 through FC 9959 or FC 9966).
|
2002
|
L25, L55
|
No
|
1 - 2 Frame Flex Track Cable A.
|
2006
|
L25, L55
|
No
|
3 - 6 Frame Flex Track Cable A.
|
2014
|
L25, L55
|
No
|
7 - 14 Frame Flex Track Cable A.
|
2018
|
L25, L55
|
No
|
9 - 18 Frame Flex Track Cable A.
|
2071
|
L25, L55
|
No
|
Flex track guide. This FC includes AXY, AXY plate, ASC to Flex track cable and new end stops.
|
2072
|
D25, D55, S25, S55, S24, S54
|
No
|
Flex track guide for expansion frame.
|
2309
|
D25, D55, L25, L55
|
No
|
TS4500 Accessor Refresh. This FC provides complete accessor assembly with HD grippers to Lxx models or models with FC 1442.
Prerequisite: FC 2071, FC 2072, or FC 9071, FC 9072.
|
2402
|
L25, L55
|
No
|
1 - 2 Frame Flex Track Cable B.
|
2406
|
L25, L55
|
No
|
3 - 6 Frame Flex Track Cable B.
|
2414
|
L25, L55
|
No
|
7 - 14 Frame Flex Track Cable B.
|
2418
|
L25, L55
|
No
|
9 - 18 Frame Flex Track Cable B.
|
2704
|
D25, D55, S25, S55, S24, S54
|
No
|
Console expansion. 26-port Ethernet switch, rack mount. This feature provides a 26-Port Ethernet switch and an attachment cable for connection to a TS3000 System Console or Master Console for Service. Up to 24 additional connections are provided by this feature.
Mutually exclusive with FC 1951 and FC 4879.
|
2715
|
L25, L55
|
No
|
TSSC Console attachment. This FC is a cable to attach a unit to the Ethernet switch provided by the TSSC.
A maximum of 43 of the FC 2715 can be included in a single TSSC facility.
FC 2704 is supported on Lx5 models if you are connecting the frame to an existing TSSC.
|
2735
|
L25, L55
|
No
|
USB Optical Drive. This feature provides a USB optical drive for use with the integrated management console (IMC). The optical drive is required for IMC code and service Knowledge Center updates.
|
2737
|
S25, S55
|
No
|
IMC Separate Power Source. This feature will allow longer distances between the IMC end panel and an FCA by supplying 2x longer Ethernet cables. For both plant and field, instructions will also be provided for moving the IMC PDU from another frame into this frame. One of the FC 9970-9985, 9989 power cords is a prerequisite to FC 2737.
|
4879
|
L25, D25
|
Yes
|
TS7700 BE Switch Mounting Hardware. This feature provides 2x Fibre Channel switch mounting hardware, including rack brackets and power cords.
The prerequisite is FC 4880. PDUs are not required with TS7700 back-end switches in a TS4500.
|
4880
|
L25, D25
|
Yes
|
TS7700 BE 16 Gb Switch. This feature provides one 16 Gb Fibre Channel switch with 24 LC Shortwave ports. The 16 Gb switch supports attachment of up to sixteen 3592 tape drives to a TS7700. Patch-panel-to-switch Fibre Channel cables are ordered against the frame that contains the tape drives by using feature codes AGK1 (if tape drives are 2 or 3 frames away from the switch) or AGKQ (if tape drives are fewer than 2 frames away from the switch).
|
6013
|
D25, D55, L25, L55
|
Yes
|
LC to LC Fibre Channel cable - 13 m (43 ft.).
|
6025
|
D25, D55, L25, L55
|
Yes
|
LC to LC Fibre Channel cable - 25 m (82 ft.).
|
6061
|
D25, D55, L25, L55
|
Yes
|
LC to LC Fibre Channel cable - 61 m (200 ft.).
|
8750
|
D55, L55
|
No
|
LTO cleaning cartridge (FC 8750). This FC is a universal cleaning cartridge.
|
8802
|
D25, L25
|
No
|
3592 cleaning cartridge.
|
9001
|
D25, D55, L25, L55
|
No
|
Driveless frame.
|
9002
|
L25, L55
|
No
|
First expansion frame attachment. This feature is used as a part of the process to add any Dxx or Sxx frame.
Prerequisites: FC 1460 and FC 1644.
|
9003
|
L25, L55
|
No
|
Additional expansion frame attachment. This feature is used as a part of the process to add any Dxx or Sxx frame.
Prerequisites: The first expansion frame attachment (FC 9002) is required.
|
9040
|
L25, L55
|
No
|
High availability library. The prerequisite is FC 9071 or FC 2071, flex track A cable FC 2002 or FC 2006 or FC 2014 or 2019, and flex track B cable
FC 2402 or FC 2406 or FC 2414 or FC 2418. |
9071
|
L25, L55
|
No
|
Flex Track Guide Base. This feature includes AXY, AXY plate, ASC to Flex track cable and new end stops. The prerequisite is FC 2002 or FC 2006 or FC 2014 or FC 2018.
|
9072
|
D25, D55, S25, S55, S54, D54
|
No
|
Flex Track Guide for expansion frame.
|
9080
|
L25, L55
|
No
|
Mixed Media Library. Library contains a mix of LTO and 3592 frames.
Prerequisite:
For Model L25, prerequisite of FC 1628 (LTO Magazine) and a minimum of one of FC 1405 or FC 1407 (LTO CE cartridge).
For Model L55, prerequisite of FC 1629 (3592 Magazine) and FC 1404 (3592 CE cartridge).
Mixed media is not supported for Lx2/Lx3.
|
9210
|
L25, L55
|
No
|
Attached to HP-UX system.
|
9211
|
L25, L55
|
No
|
Attached to Solaris system.
|
9212
|
L25, L55
|
No
|
Attached to Microsoft Windows system.
|
9213
|
L25, L55
|
No
|
Attached to another system that is not an IBM system.
|
9215
|
L25, L55
|
No
|
Attached to Linux system.
|
9217
|
L25, L55
|
No
|
Attached to z/OS, TS7700.
|
9218
|
L25, L55
|
No
|
Attached to High Performance Storage System (HPSS).
|
9400
|
L25, L55
|
No
|
Attached to IBM i5/OS or IBM OS/400® system.
|
9600
|
L25, L55
|
No
|
Attached to IBM AIX® system.
|
9607
|
D25, D55, L25, L55
|
No
|
3588 F7C plant install.
|
9608
|
D25, D55, L25, L55
|
No
|
3588 F7C field install.
|
9690
|
D25, D55, L25, L55
|
No
|
3588/3592 drive. Field install. FC 9690 is a counting feature code. Prerequisite: FC 152x (drive mounting kit). Each FC 152x supports up to four
of FC 969x.
|
9692
|
L25, L55
|
No
|
3592 E07/EH7 tape drive. Plant install. FC 9692 is a manufacturing routing code. Prerequisite: FC 152x (drive mounting kit).
|
9695
|
L55, D55
|
No
|
3588 F5A/F5C tape drive. Plant install. FC 9695 is a manufacturing routing code. Prerequisite: FC 152x (drive mounting kit).
|
9697
|
L55, D55
|
No
|
3588 F6A/F6C tape drive. Plant install. FC 9697 is a manufacturing routing code. Prerequisite: FC 152x (drive mounting kit).
|
9699
|
L25, D25
|
No
|
3592 EH8 tape drive - plant install
FC 9699 is a manufacturing routing code. Prerequisite: FC 152x (drive mounting kit).
|
9700
|
D25, D55, L25, L55
|
No
|
No host attach cables - from plant.
|
9704
|
L55, D25
|
No
|
3592 55E tape drive. Plant install. FC 9704 is a manufacturing routing code. Prerequisite: FC 152x (drive mounting kit).
|
9705
|
L55, D25
|
No
|
3592 55F tape drive. Plant install. FC 9705 is a manufacturing routing code. Prerequisite: FC 152x (drive mounting kit).
|
9735
|
L25, L55
|
No
|
IMC broadband Call Home. This feature indicates that you allow broadband Call Home, so no additional remote service tools are required.
|
9954
|
D25, D55, L25, L55, S25, S55
|
No
|
NEMA L6-30 Power Cord. FC 9954 is used with PDU FCs 1751 or 1951. FC 9954 provides 1x power cord for FC 1751 and 2x power cords for FC 195x.
|
9955
|
D25, D55, L25, L55, S25, S55
|
No
|
RS 3750DP power cord. FC 9955 is used with PDU FCs 1751 or 1951. FC 9955 provides 1x power cord for FC 1751 and 2x power cords for FC 195x.
|
9956
|
D25, D55, L25, L55, S25, S55
|
No
|
IEC 309 power cord. FC 9956 is used with PDU FCs 1751 or 1951. FC 9956 provides 1x power cord for FC 1751 and 2x power cords for FC 195x.
|
9957
|
D25, D55, L25, L55, S25, S55
|
No
|
4.3 m power cord (Australia/NZ). FC 9957 is used with PDU FCs 1751 or 1951. FC 9957 provides 1x power cord for FC 1751 and 2x power cords for FC 195x.
|
9958
|
D25, D55, L25, L55, S25, S55
|
No
|
4.3 m power cord (Korean). FC 9958 is used with PDU FCs 1751 or 1951. FC 9958 provides 1x power cord for FC 1751 and 2x power cords for FC 195x.
|
9959
|
D25, D55, L25, L55, S25, S55
|
No
|
Unterminated power cord. FC 9959 is used with PDU FCs 1751 or 1951. FC 9959 provides 1x power cord for FC 1751 and 2x power cords for FC 195x.
|
9966
|
D25, D55, L25, L55, S25, S55
|
No
|
Unterminated power cords (China CCC cert). FC 9966 is used with PDU FCs 1751 or 1951. FC 9966 provides 1x power cord for FC 1751 and 2x power cords for FC 195x.
|
9970
|
D25, D55, L25, L55, S25, S55
|
No
|
Dual 4.3 m power cord (international, 250 VAC 16A single phase, watertight connector, IEC-309). FC 9970 includes model-dependent contents. For countries other than the United States and Canada, the connector is rated at 16A (plug type Hubbell HBL316P6W or equivalent) for connection to Hubbell type HBL316R6W or equivalent receptacles.
In the United States and Canada, the connector is rated at 20A (plug type Hubbell HBL320P6W) for connection to Hubbell type HBL320R6W or equivalent receptacles. This power cord is the default power cord for all countries other than those countries that are specified for FC 9972 and FCs 9976 through 9983. This power cord can be used for all countries, except the following countries:
•Argentina
•Australia
•Brazil
•Canada
•China
•Japan
•Korea
•New Zealand
•Philippines
•South Africa
•Taiwan
FC 9970 must be ordered with FC 1901.
Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC2737
|
9972
|
D25, D55, L25, L55
|
No
|
Dual 4.3 m power cords (250 VAC 15, non-watertight twist lock connector, Nema L6-15P mates with L6-15R). FC 9972 includes model-dependent contents. It is the default power cord for US, Canada, Japan, Korea, Philippines, and Taiwan.
Corequisite: FC 9972 must be ordered with FC 1901.
Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC2737.
|
9976
|
D25, D55, L25, L55
|
No
|
Dual 4.3 m power cords with 10 Amp/250 Vac, non-watertight IRAM 2073 plug. FC 9976 is for Argentina.
|
9977
|
D25, D55, L25, L55
|
No
|
Dual 4.3 m power cords with 15 Amp/250 Vac with earth pin InMetro NBR 14136 plug. FC 9977 is for Brazil.
Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC2737.
|
9978
|
D25, D55, L25, L55
|
No
|
Dual 4.3 m power cords with 10 Amp/250 Vac AZ/NZS 3112/2000 plug.
FC 9978 is for Australia and New Zealand. Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC2737.
|
9979
|
D25, D55, L25, L55
|
No
|
Dual 4.3 m power cords with 15 Amp/250 Vac JIS C8303, C8306 plug.
FC 9979 is for Japan. Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC2737.
|
9980
|
D25, D55, L25, L55
|
No
|
Dual 4.3 m power cords with 10 Amp/250 Vac, GB 2099.1, 1002 plug.
FC 9980 is for China. Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC2737.
|
9981
|
D25, D55, L25, L55
|
No
|
Dual 4.3 m power cords with 15 Amp/250 Vac with earth pin KS C8305, K60884-1 plug. FC 9981 is for Korea.
Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC2737.
|
9982
|
D25, D55, L25, L55
|
No
|
Dual 4.3 m power cords with 10 Amp/250 Vac CNS 10917-3 plug. FC 9982 is for Taiwan.
Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC2737.
|
9983
|
D25, D55, L25, L55
|
No
|
Dual 4.3 m power cords with 10 Amp/250 Vac SANS 164-1 plug. FC 9983 is for South Africa.
Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC2737.
|
9984
|
D25, D55, L25, L55
|
No
|
Dual 4.3 m power cords with 15 Amp/250V single phase power cord assemblies, NEMA L6-20P non-watertight twistlock 20A plug.
FC 9984 is 2x power cords, which are UL/CSA certified for use in US and Canada. These power cords mate with client-supplied NEMA L6-20R receptacles.
Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC2737.
|
9985
|
D25, D55, L25, L55
|
No
|
Dual 4.3 m power cords with 15 Amp/250V single phase power cord assemblies with watertight 15A Russellstoll plug.
FC 9985 is 2x power cords, which are UL/CSA certified for use in US and Canada. These power cords mate with client-supplied Russellstoll 3743U2 or 9R23U2W receptacles.
Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC2737.
|
9989
|
D25, D55, L25, L55
|
No
|
Dual 4.3 m power cords with 10Amp/250V with IEC 309 C14 plug.
FC 9989 is for use with adjacent frame PDUs (FC 1951) or external (client-supplied) PDUs.
Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC2737.
|
AGKQ
|
L25, D25
|
No
|
3-meter OM3 quad cables. This FC requires FC 1521 or FC 1522 or FC 1523 or FC 1524.
|
AGK1
|
D25, D55, L25, L55
|
No
|
10-meter OM3 fiber Cable (LC). This feature provides a 10-meter 50.0/125 micrometer fiber optic cable that is terminated with LC Duplex connectors.
|
AGK2
|
D25, D55, L25, L55
|
No
|
25-meter OM3 fiber Cable (LC). This feature provides a 25-meter 50.0/125 micrometer fiber optic cable that is terminated with LC Duplex connectors.
|
AGK3
|
D25, D55, L25, L55
|
No
|
80-meter OM3 fiber Cable (LC). This feature provides an 80-meter 50.0/125 micrometer fiber optic cable that is terminated with LC Duplex connectors.
|
Tip: The device driver is available for each operating system from IBM Fix Central:
|
Model
|
Width1
|
Depth
|
Height
|
L25, L55, D25, D55, S25, S55, S24, and S54 (on casters)
|
782 mm (30.8 in.)
|
1,212 mm (47.72 in.)
|
1,800 mm (70.9 in.)
|
L25, L55, D25, D55, S25, S55, S24, and S54 frames with top rack
|
782 mm (30.8 in.)
|
1,212 mm (47.72 in.)
|
2,320 mm (91.34 in.)
|
L25, L55, D25, D55, S25, S55, S24, and S54 frame with covers
|
782 mm (30.8 in.)
|
1,212 mm (47.72 in.)
|
1,800 mm (70.9 in.)
|
L25, L55, D25, D55, S25, S55, S24, and S54 frame without covers
|
725 mm (28.5 in.)
|
1,212 mm (47.72 in.)
|
1,800 mm (70.9 in.)
|
Model and position
|
Minimum weight of frame (with no tape drives or cartridges)1
|
Maximum weight of frame (with maximum tape drives and cartridges) 2
|
L25 Position 1 (leftmost frame)
|
407.8 kg (899 lb.)
|
586.5 kg (1,293 lb.)
|
L25 Position 2+
|
407.8 kg (899 lb.)
|
630.5 kg (1,390 lb.)
|
D25 Position 1 (leftmost frame)
|
310.7 kg (685 lb.)
|
500 kg (1,103 lb.)
|
D25 Position 2+
|
310.7 kg (685 lb.)
|
552.5 kg (1,218 lb.)
|
L55 Position 1 (leftmost frame)
|
410 kg (904 lb.)
|
592 kg (1,305 lb.)
|
L55 Position 2+
|
410 kg (904 lb.)
|
637 kg (1,404 lb.)
|
D55 Position 1 (leftmost frame)
|
316 kg (697 lb.)
|
503.5 kg (1,110 lb.)
|
D55 Position 2+
|
316 kg (697 lb.)
|
557 kg (1,228 lb.)
|
S25 Position 1 (leftmost frame)
|
299 kg (660 lb.)
|
491.2 kg (1,083 lb.)
|
S25 Position 2+
|
299 kg (660 lb.)
|
540.2 kg (1,191 lb.)
|
S55 Position 1 (leftmost frame)
|
304 kg (670 lb.)
|
509.4 kg (1,123 lb.)
|
S55 Position 2+
|
304 kg (670 lb.)
|
564 kg (1,244 lb.)
|
S24 Position 2+
|
285.8 kg (630 lb.)
|
526.2 kg (1160 lb.)
|
S54 Position 2+
|
290.3 kg (640 lb.)
|
562.5 kg (1240 lb.)
|
TR1 Weight of top rack (empty)3
|
24.5 kg (54 lb.)
|
24.5 kg (54 lb.)
|
Weights that are listed for the Lx5 frames include the accessor, IMC, side doors, and side panels. After the initial library installation, these parts can be moved to other frames within the library string to shift part of the weight to other frames.
|
Power requirements
|
220 V AC line cord
|
AC line voltage
|
200 - 240 V AC (nominal)
|
AC line frequency
|
50 - 60 Hz
|
Nominal power
|
1.4 kW
|
Line current
|
8.0 A
|
kVA
|
1.6 kVA
|