CPC drawer
|
CPC drawer 0
|
CPC drawer 1
|
CPC drawer 2
|
CPC drawer 3
|
Installation order
|
First
|
Second
|
Third
|
Fourth
|
Position in Frame A
|
A15A
|
A19A
|
A23A
|
A27A
|
Tip: STP is available as FC 1021. It is implemented in the Licensed Internal Code (LIC), and allows multiple servers to maintain time synchronization with each other and synchronization to an ETS. For more information, see the following publications:
•Server Time Protocol Planning Guide, SG24-7280
•Server Time Protocol Implementation Guide, SG24-7281
•Server Time Protocol Recovery Guide, SG24-7380
|
Model / CPC drawers
|
Installed PUs
|
Standard SAPs
|
Minimum spare PUs
|
Maximum characterized PUs
|
Integrated firmware processor (IFP)
|
|
N30 / 1
|
39 (1 x 39)
|
6
|
2
|
30
|
1
|
|
N63 / 2
|
78 (2 x 39)
|
12
|
2
|
63
|
1
|
|
N96 / 3
|
117 (3 x 39)
|
18
|
2
|
96
|
1
|
|
NC9 / 4
|
156 (4 x 39)
|
24
|
2
|
129
|
1
|
|
NE1 / 4
|
168 (4 x 42)
|
24
|
2
|
141
|
1
|
Model
|
Number of CPC drawer
|
Customer memory (GB)
|
N30
|
1
|
64 - 2464
|
N63
|
2
|
64 - 5024
|
N96
|
3
|
64 - 7584
|
NC9
|
4
|
64 - 10144
|
NE1
|
4
|
64 - 10144
|
Granularity (GB)
|
Customer memory (GB)
|
32
|
64 - 192
|
64
|
256 - 448
|
96
|
448 - 928
|
128
|
928 - 1440
|
256
|
1440 - 6048
|
512
|
6560 - 10144
|
Customer Memory
|
Model N30
|
Model N63
|
Model N96
|
Model NC9 and Model NE1
|
||||||
(GB)
|
CPC drawer 0
|
CPC drawer 0
|
CPC drawer 1
|
CPC drawer0
|
CPC drawer1
|
CPC drawer 2
|
CPC drawer 0
|
CPC drawer 1
|
CPC drawer 2
|
CPC drawer 3
|
64
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
96
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
128
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
160
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
192
|
480
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
256
|
480
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
640
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
384
|
640
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
448
|
960
|
480
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
544
|
960
|
480
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
640
|
960
|
480
|
480
|
320
|
320
|
320
|
320
|
320
|
320
|
320
|
736
|
1280
|
640
|
480
|
480
|
320
|
320
|
320
|
320
|
320
|
320
|
832
|
1280
|
640
|
640
|
480
|
480
|
320
|
320
|
320
|
320
|
320
|
928
|
1280
|
640
|
640
|
480
|
480
|
320
|
320
|
320
|
320
|
320
|
1056
|
1920
|
960
|
640
|
480
|
480
|
480
|
480
|
320
|
320
|
320
|
1184
|
1920
|
960
|
640
|
640
|
480
|
480
|
480
|
480
|
320
|
320
|
1312
|
1920
|
960
|
960
|
640
|
640
|
480
|
480
|
480
|
480
|
320
|
1440
|
1920
|
960
|
960
|
640
|
640
|
640
|
480
|
480
|
480
|
480
|
1696
|
2560
|
1280
|
960
|
960
|
640
|
640
|
640
|
640
|
480
|
480
|
1952
|
2560
|
1280
|
1280
|
960
|
960
|
640
|
640
|
640
|
640
|
640
|
2208
|
3200
|
1920
|
1280
|
960
|
960
|
960
|
960
|
640
|
640
|
640
|
2464
|
3200
|
1920
|
1280
|
1280
|
960
|
960
|
960
|
960
|
640
|
640
|
2720
|
N/A
|
1920
|
1920
|
1280
|
1280
|
960
|
960
|
960
|
960
|
640
|
2976
|
N/A
|
1920
|
1920
|
1280
|
1280
|
1280
|
960
|
960
|
960
|
960
|
3232
|
N/A
|
2560
|
1920
|
1920
|
1280
|
1280
|
1280
|
1280
|
960
|
960
|
3488
|
N/A
|
2560
|
1920
|
1920
|
1280
|
1280
|
1280
|
1280
|
960
|
960
|
3744
|
N/A
|
2560
|
2560
|
1920
|
1920
|
1280
|
1280
|
1280
|
1280
|
960
|
4000
|
N/A
|
2560
|
2560
|
1920
|
1920
|
1280
|
1280
|
1280
|
1280
|
1280
|
4256
|
N/A
|
3200
|
2560
|
1920
|
1920
|
1920
|
1920
|
1280
|
1280
|
1280
|
4512
|
N/A
|
3200
|
2560
|
1920
|
1920
|
1920
|
1920
|
1280
|
1280
|
1280
|
4768
|
N/A
|
3200
|
3200
|
2560
|
1920
|
1920
|
1920
|
1920
|
1280
|
1280
|
5024
|
N/A
|
3200
|
3200
|
2560
|
1920
|
1920
|
1920
|
1920
|
1280
|
1280
|
5280
|
N/A
|
N/A
|
N/A
|
2560
|
2560
|
1920
|
1920
|
1920
|
1920
|
1280
|
5536
|
N/A
|
N/A
|
N/A
|
2560
|
2560
|
1920
|
1920
|
1920
|
1920
|
1280
|
5792
|
N/A
|
N/A
|
N/A
|
2560
|
2560
|
2560
|
1920
|
1920
|
1920
|
1920
|
6048
|
N/A
|
N/A
|
N/A
|
2560
|
2560
|
2560
|
1920
|
1920
|
1920
|
1920
|
6560
|
N/A
|
N/A
|
N/A
|
3200
|
2560
|
2560
|
2560
|
1920
|
1920
|
1920
|
7072
|
N/A
|
N/A
|
N/A
|
3200
|
3200
|
2560
|
2560
|
2560
|
1920
|
1920
|
7584
|
N/A
|
N/A
|
N/A
|
3200
|
3200
|
3200
|
2560
|
2560
|
2560
|
1920
|
8096
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
2560
|
2560
|
2560
|
2560
|
8608
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
3200
|
2560
|
2560
|
2560
|
9120
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
3200
|
3200
|
2560
|
2560
|
9632
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
3200
|
3200
|
3200
|
2560
|
10144
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
3200
|
3200
|
3200
|
3200
|
Model
|
Standard memory (GB)
|
Flexible memory (GB)
|
N30
|
64 - 2464
|
N/A
|
N63
|
64 - 5024
|
64 - 2464
|
N96
|
64 - 7584
|
64 - 5024
|
NC9
|
64 - 10144
|
64 - 7584
|
NE1
|
64 - 10144
|
64 - 7584
|
Memory Increment (GB)
|
Flexible memory (GB)
|
32
|
64 - 192
|
64
|
192 - 448
|
96
|
448 - 928
|
128
|
928 - 1440
|
256
|
1440 - 6048
|
512
|
6048 - 7584
|
Memory
|
z13 feature code
|
Pre-planned memory
Charged when physical memory is installed.
Used for tracking the quantity of physical increments of plan-ahead memory capacity.
|
FC 1996 - 16 GB
FC 1990 - 32 GB
|
Pre-planned memory activation
Charged when plan-ahead memory is enabled.
Used for tracking the quantity of increments of plan-ahead memory that are being activated.
|
FC1901
|
Reminder: Normal memory upgrades use the plan-ahead memory first.
|
Model
|
Drawers /
PUs
|
CPs
|
IFLs/uIFL
|
ICFs
|
zIIPs
|
Add. SAPs
|
Std. SAPs
|
Spares
|
IFP
|
N30
|
1/39
|
0 - 30
|
0 - 30
0 - 39 |
0 - 30
|
0 - 20
|
0 - 4
|
6
|
2
|
1
|
N63
|
2/78
|
0 - 63
|
0 - 63
0 - 62 |
0 - 63
|
0 - 42
|
0 - 8
|
12
|
2
|
1
|
N96
|
3/117
|
0 - 96
|
0 - 96
0 - 95 |
0 - 96
|
0 - 64
|
0 - 12
|
18
|
2
|
1
|
NC9
|
4/156
|
0 - 129
|
0 - 129
0 - 128 |
0 - 129
|
0 - 86
|
0 - 16
|
24
|
2
|
1
|
NE1
|
4/168
|
0 - 141
|
0 - 141
0 - 140 |
0 - 141
|
0 - 94
|
0 - 16
|
24
|
2
|
1
|
To 2964
From 2964
|
Model N30
|
Model N63
|
Model N96
|
Model NC9
|
Model NE11
|
Model N30
|
-
|
Yes
|
Yes
|
Yes
|
Yes
|
Model N63
|
-
|
-
|
Yes
|
Yes
|
Yes
|
Model N96
|
-
|
-
|
-
|
Yes
|
Yes
|
Model NC9
|
-
|
-
|
-
|
-
|
Yes
|
Important: Upgrades from z Enterprise EC12 (zEC12) and zEnterprise 196 (z196) are always disruptive.
|
To 2964
From 2817
|
Model N30
|
Model N63
|
Model N96
|
Model NC9
|
Model NE1
|
Model M15
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Model M32
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Model M49
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Model M66
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Model M80
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
To 2964
From 2827
|
Model N30
|
Model N63
|
Model N96
|
Model NC9
|
Model NE1
|
Model H20
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Model H43
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Model H66
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Model H89
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Model HA1
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
To
From
|
CP
|
IFL
|
Unassigned IFL
|
ICF
|
zAAP
|
zIIP
|
SAP
|
CP
|
-
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
IFL
|
Yes
|
-
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Unassigned IFL
|
Yes
|
Yes
|
-
|
Yes
|
Yes
|
Yes
|
Yes
|
ICF
|
Yes
|
Yes
|
Yes
|
-
|
Yes
|
Yes
|
Yes
|
zAAP
|
Yes
|
Yes
|
Yes
|
Yes
|
-
|
Yes
|
Yes
|
zIIP
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
-
|
Yes
|
SAP
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
-
|
Consideration: Within a z13, all CPs have the same capacity identifier. Specialty engines (IFLs, zIIPs, and ICFs) operate at full speed.
|
z13
|
Model capacity identifier
|
Model N30
|
701 - 730, 601 - 630, 501 - 530, and 401 - 430
|
Model N63
|
701 - 763, 601 - 630, 501 - 530, and 401 - 430
|
Model N96
|
701 - 796, 601 - 630, 501 - 530, and 401 - 430
|
Model NC9
|
701 - 7C9, 601 - 630, 501 - 530, and 401 - 430
|
Model NE1
|
701 - 7E1, 601 - 630, 501 - 530, and 401 - 430
|
Important: On z13, model capacity identifier 400 is used for IFL- or ICF-only configurations.
|
Remember: Activation of CBU for CPs, IFLs, ICFs, zIIPs, and SAPs can be activated together with On/Off Capacity on Demand temporary upgrades. Both facilities can be on a single system, and can be activated simultaneously.
|
Model
|
Total PUs available
|
CBU
CPs
min - max
|
CBU
IFLs
min - max
|
CBU
ICFs
min - max
|
CBU
zIIPs
min - max
|
CBU
SAPs
min - max
|
Model N30
|
30
|
0 - 30
|
0 - 30
|
0 - 30
|
0 - 20
|
0 - 4
|
Model N63
|
63
|
0 - 63
|
0 - 63
|
0 - 63
|
0 - 42
|
0 - 8
|
Model N96
|
96
|
0 - 96
|
0 - 96
|
0 - 96
|
0 - 64
|
0 - 12
|
Model NC9
|
129
|
0 - 129
|
0 - 129
|
0 - 129
|
0 - 86
|
0 - 16
|
Model NE1
|
141
|
0 - 141
|
0 - 141
|
0 - 1E1
|
0 - 94
|
0 - 16
|
Tip: The exact power consumption for your system varies. The object of the tool is to estimate the power requirements to aid you in planning for your system installation. Actual power consumption after installation can be confirmed by using the HMC Monitors Dashboard task.
|
Temperature
|
Three CPC drawer typical configuration
|
Four CPC drawer typical configuration
|
Four CPC drawer maximum power configuration
|
Water-cooled system power in normal room/hot room
|
|||
|
12.9 kW/14.1 kW
|
17.4 kW/19.0 kW
|
24.7 kW/26.3 kW
|
Inlet air temperature
|
Heat to water and as % of total system heat load
|
||
18°C (64°F)
|
7.3 kW (57%)
|
9.8 kW (56%)
|
12.6 kW (51%)
|
23°C (73°F)
|
9.5 kW (74%)
|
12.6 kW (72%)
|
15.6 kW (63%)
|
27°C (80.6°F)
|
11.5 kW (89%)
|
14.8 kW (85%)
|
18.0 kW (73%)
|
32°C (89.6°F)
(hot room) |
14.8 kW (105%)
|
18.2 kW (96%)
|
21.6 kW (82%)
|
Description
|
Model N30
|
Model N63
|
Model N96
|
Model NC9
|
Model NE1
|
Number of CPC drawers
|
1
|
2
|
3
|
4
|
4
|
Number of SCMs
|
8
|
16
|
24
|
32
|
32
|
Total number of PUs
|
39
|
78
|
117
|
156
|
168
|
Maximum number of characterized PUs
|
30
|
63
|
96
|
129
|
141
|
Number of CPs
|
0 - 30
|
0 - 63
|
0 - 96
|
0 - 129
|
0 - 141
|
Number of IFLs
|
0 - 30
|
0 - 63
|
0 - 96
|
0 - 129
|
0 - 141
|
Number of ICFs
|
0 - 30
|
0 - 63
|
0 - 96
|
0 - 129
|
0 - 141
|
Number of zIIPs
|
0 - 20
|
0 - 42
|
0 - 64
|
0 - 86
|
0 - 94
|
Standard SAPs
|
6
|
12
|
18
|
24
|
24
|
Additional SAPs
|
0 - 4
|
0 - 8
|
0 - 12
|
0 - 16
|
0 - 16
|
Number of IFP
|
1
|
1
|
1
|
1
|
1
|
Standard spare PUs
|
2
|
2
|
2
|
2
|
2
|
Enabled memory sizes
|
64 - 2464 GB
|
64 - 5024 GB
|
64 - 7584 GB
|
64 - 10144 GB
|
64 - 10144 GB
|
Flexible memory sizes
|
N/A
|
64 - 2464 GB
|
64 - 5024 GB
|
64 - 7584 GB
|
64 - 7584 GB
|
L1 cache per PU
|
96/128 KB(I/D)
|
96/128 KB(I/D)
|
96/128 KB(I/D)
|
96/128 KB(I/D)
|
96/128 KB(I/D)
|
L2 cache per PU
|
2/2 MB (I/D)
|
2/2 MB (I/D)
|
2/2 MB (I/D)
|
2/2 MB (I/D)
|
2/2 MB (I/D)
|
L3 shared cache per PU chip
|
64 MB
|
64 MB
|
64 MB
|
64 MB
|
64 MB
|
L4 shared cache per node
|
480 MB
|
480 MB
|
480 MB
|
480 MB
|
480 MB
|
L4 NIC directory per node
|
224 MB
|
224 MB
|
224 MB
|
224 MB
|
224 MB
|
Cycle time (ns)
|
0.2
|
0.2
|
0.2
|
0.2
|
0.2
|
Clock frequency
|
5.0 GHz
|
5.0 GHz
|
5.0 GHz
|
5.0 GHz
|
5.0 GHz
|
Maximum number of PCIe fanouts
|
10
|
20
|
30
|
40
|
40
|
Maximum number of IFB fanouts
|
4
|
8
|
12
|
16
|
16
|
I/O interface per IFB cable
|
6 GBps
|
6 GBps
|
6 GBps
|
6 GBps
|
6 GBps
|
I/O interface per PCIe cable
|
16 GBps
|
16 GBps
|
16 GBps
|
16 GBps
|
16 GBps
|
Number of support elements
|
2
|
2
|
2
|
2
|
2
|
External AC power
|
3 phase
|
3 phase
|
3 phase
|
3 phase
|
a3 phase
|
Optional external DC
|
520 V/380 V
|
520 V/380 V
|
520 V/380 V
|
520 V/380 V
|
520 V/380 V
|
Internal Battery Feature
|
Optional
|
Optional
|
Optional
|
Optional
|
Optional
|